Question Details

A machine of mass 100 kg is subjected to an external harmonic force with a frequency of 40 rad/s. The designer decides to mount the machine on an isolator to reduce the force transmitted to the foundation. The isolator can be considered as a combination of stiffness (K) and damper (damping factor, ζ) in parallel. The designer has the following four isolators :

1) k = 640 kN/m, ζ = 0.70

2) k = 640 kN/m, ζ = 0.07

3) k = 22.5 kN/m, ζ = 0.70

4) k = 22.5 kN/m, ζ = 0.07

Arrange the isolators in the ascending order of the force transmitted to the foundation.

Options

A

1-3-4-2

B

1-3-2-4

C

4-3-1-2

D

4-3-1-2

Show Answer
Correct Answer
D 4-3-1-2

Solution :

The correct option is 4-3-1-2.

Analysis of the System Parameters:
We are given:
- Mass of the machine, m = 100 kg
- Excitation frequency, ω = 40 rad/s
- Stiffness values k and damping factors ζ for four different isolators.

Step 1: Calculate the Natural Frequency and Frequency Ratio for Each Stiffness Value
As analyzed from the provided diagram, we calculate the natural frequency (ωn) and the frequency ratio (r) for each set of stiffness values.

For Isolators 1 and 2:
Stiffness k = 640 kN/m = 640000 N/m
The natural frequency is calculated as:
ω n = k m = 640000 100 = 80 rad/s
The frequency ratio is:
r = ω ω n = 40 80 = 0.5

For Isolators 3 and 4:
Stiffness k = 22.5 kN/m = 22500 N/m
The natural frequency is calculated as:
ω n = k m = 22500 100 = 15 rad/s
The frequency ratio is:
r = ω ω n = 40 15 ≈ 2.667

Step 2: Understand Force Transmissibility (ε) Behavior
The force transmissibility ratio (ε), representing the ratio of force transmitted to the foundation (Ft) to the excitation force (F0), is defined as:
ε = F t F 0 = 1 + ( 2 ζ r ) 2 ( 1 - r 2 ) 2 + ( 2 ζ r ) 2
Based on the standard transmissibility curves shown in the diagram:
1. At the critical boundary r=2, the transmissibility is exactly 1, independent of the damping factor ζ.
2. For r<2 (amplification region): The transmissibility ratio is greater than 1 (ε>1). In this region, higher damping reduces transmissibility (as ζ increases, ε decreases).
3. For r>2 (isolation region): The transmissibility ratio is less than 1 (ε<1). In this region, higher damping increases transmissibility (as ζ increases, ε increases).

Step 3: Compare and Arrange the Isolators
Let us evaluate each isolator based on these regions:
- Isolator 1: r = 0.5, ζ = 0.70
Since r=0.5<2, we have ε1>1. Because damping is high, transmissibility is moderately reduced but remains above 1.
- Isolator 2: r = 0.5, ζ = 0.07
Since r=0.5<2, we have ε2>1. Because damping is very low, transmissibility is higher than in Isolator 1 (ε2>ε1).
- Isolator 3: r = 2.667, ζ = 0.70
Since r=2.667>2, we have ε3<1. In this isolation zone, higher damping increases transmissibility, so ε3 is larger than it would be with lower damping.
- Isolator 4: r = 2.667, ζ = 0.07
Since r=2.667>2, we have ε4<1. Because damping is very low in this zone, it offers the lowest transmissibility (ε4<ε3).

Combining these relationships as shown in the diagram:
ε 4 < ε 3 < 1 < ε 1 < ε 2
Therefore, the ascending order of the force transmitted to the foundation is:
4 - 3 - 1 - 2

Transparent Access on Mindyard

Built for Learners & Educators Alike

Completely free for students. Educators & coaching institutes get 2 months free Pro trial to create tests.

FREE FOR STUDENTS

Practice & Learn Free for Students

Access unlimited practice questions, detailed step-by-step solutions, and exam study materials — completely free for students.

  • Unlimited mock tests & question bank practice
  • Full access to curated study library & formula notes
  • 100% free for students • No credit card required
2 MONTHS FREE TRIAL

Educators & Coaching Institutes

Create and conduct professional online assessments with AI question generation, tab proctoring, and comprehensive batch management.

  • AI question uploader & rapid test generator
  • Anti-cheating tab proctoring & performance reports
  • Full Pro access free for 60 days • No upfront commitment
Discover more resources

You may also like

Mock Tests

View All
  • GATE
  • intermediate
  • 3 hours
  • mechanical engineering

The GATE 2026 Mechanical Engineering (ME) examination scheduled for 14 February 2026 is one of the most important national-level competitive exams for engineering graduates aspiring for higher education and prestigious career opportunities in PSU and research organizations. Conducted annually at the national level, the GATE Mechanical Engineering paper evaluates candidates on core subjects such as Engineering Mechanics, Thermodynamics, Fluid Mechanics, Strength of Materials, Manufacturing Processes, and Machine Design, along with General Aptitude and Engineering Mathematics. This examination is a gateway for admission into M.Tech/Ph.D. programs at IITs, NITs, IISc, and other top institutions, as well as recruitment in major Public Sector Undertakings (PSUs) like ONGC, NTPC, BHEL, IOCL, and more. The GATE ME 2026 paper will test conceptual understanding, analytical thinking, and problem-solving ability, making strong preparation essential for success. Candidates are advised to practice previous year papers, mock tests, and focus on conceptual clarity for high scoring performance. This exam on 14/02/2026 is a crucial opportunity for mechanical engineering aspirants to secure their future in academia and industry.

  • GATE
  • intermediate
  • 3 hours
  • mechanical engineering

Strengthen your preparation with this GATE 2025 Mechanical Engineering (ME) test, covering core subjects such as thermodynamics, fluid mechanics, strength of materials, theory of machines, and manufacturing engineering. With a well-balanced mix of conceptual and numerical questions, this test helps enhance problem-solving ability and technical understanding. Aligned with the latest exam pattern, it is ideal for improving accuracy, speed, and overall exam readiness.

Ask AI Tutor
5 left
Q1 View Question & Options
AI Tutor is solving this question...
Reading question context & options...
Ask your own doubt or choose a quick prompt: