Question Details

In a vapor compression refrigeration cycle, the refrigerant enters the compressor in saturated vapor state at evaporator pressure, with specific enthalpy equal to 250 kJ/kg. The exit of the compressor is superheated at condenser pressure with specific enthalpy equal to 300 kJ/kg. At the condenser exit, the refrigerant is throttled to the evaporator pressure. The coefficient of performance (COP) of the cycle is 3. If the specific enthalpy of the saturated liquid at evaporator pressure is 50 kJ/kg, then the dryness fraction of the refrigerant at entry to evaporator is _________.

Options

A

0.2

B

0.25

C

0.3

D

0.35

Show Answer
Correct Answer
B 0.25

Solution :

The correct option is 0.25.

1. Understanding the Process States:
In the temperature-entropy (T-s) diagram shown in the image, the state points represent the key stages of the vapor compression refrigeration cycle:
- State 1: Entry to the compressor (saturated vapor state at evaporator pressure). Here, the specific enthalpy is:
h1=250 kJ/kg
- State 2: Exit of the compressor (superheated state at condenser pressure). Here, the specific enthalpy is:
h2=300 kJ/kg
- State 3: Condenser exit (saturated liquid state at condenser pressure).
- State 4: Entry to the evaporator after the throttling process (represented by the vertical dashed line from State 3 to State 4).

2. Determining Specific Enthalpy at State 4:
The work input to the compressor (W) is given by the difference in enthalpy between the compressor exit and entry:
W=h2-h1=300-250=50 kJ/kg
The Coefficient of Performance (COP) of the cycle is defined as:
COP=Refrigeration EffectWork Input=h1-h4h2-h1
Given that the COP of the cycle is 3, we can substitute the values to find the refrigeration effect:
3=250-h450
Multiplying both sides by 50:
150=250-h4
Rearranging the equation yields:
h4=250-150=100 kJ/kg

3. Calculating the Dryness Fraction:
State 4 lies in the two-phase (liquid-vapor) region at the evaporator pressure. The enthalpy of the mixture at State 4 is expressed in terms of the dryness fraction (x) as:
h4=hf4+x(hg4-hf4)
where:
- hf4 is the specific enthalpy of the saturated liquid at the evaporator pressure, given as:
hf4=50 kJ/kg
- hg4 is the specific enthalpy of the saturated vapor at the evaporator pressure, which corresponds to the compressor inlet enthalpy at State 1:
hg4=h1=250 kJ/kg
Substitute these values into the dryness fraction formula:
100=50+x(250-50)
Subtract 50 from both sides:
50=200x
Solving for x:
x=50200=0.25
Thus, the dryness fraction of the refrigerant at the entry to the evaporator is 0.25.

Transparent Access on Mindyard

Built for Learners & Educators Alike

Completely free for students. Educators & coaching institutes get 2 months free Pro trial to create tests.

FREE FOR STUDENTS

Practice & Learn Free for Students

Access unlimited practice questions, detailed step-by-step solutions, and exam study materials — completely free for students.

  • Unlimited mock tests & question bank practice
  • Full access to curated study library & formula notes
  • 100% free for students • No credit card required
2 MONTHS FREE TRIAL

Educators & Coaching Institutes

Create and conduct professional online assessments with AI question generation, tab proctoring, and comprehensive batch management.

  • AI question uploader & rapid test generator
  • Anti-cheating tab proctoring & performance reports
  • Full Pro access free for 60 days • No upfront commitment
Discover more resources

You may also like

Mock Tests

View All
  • GATE
  • intermediate
  • 3 hours
  • mechanical engineering

The GATE 2026 Mechanical Engineering (ME) examination scheduled for 14 February 2026 is one of the most important national-level competitive exams for engineering graduates aspiring for higher education and prestigious career opportunities in PSU and research organizations. Conducted annually at the national level, the GATE Mechanical Engineering paper evaluates candidates on core subjects such as Engineering Mechanics, Thermodynamics, Fluid Mechanics, Strength of Materials, Manufacturing Processes, and Machine Design, along with General Aptitude and Engineering Mathematics. This examination is a gateway for admission into M.Tech/Ph.D. programs at IITs, NITs, IISc, and other top institutions, as well as recruitment in major Public Sector Undertakings (PSUs) like ONGC, NTPC, BHEL, IOCL, and more. The GATE ME 2026 paper will test conceptual understanding, analytical thinking, and problem-solving ability, making strong preparation essential for success. Candidates are advised to practice previous year papers, mock tests, and focus on conceptual clarity for high scoring performance. This exam on 14/02/2026 is a crucial opportunity for mechanical engineering aspirants to secure their future in academia and industry.

  • GATE
  • intermediate
  • 3 hours
  • mechanical engineering

Strengthen your preparation with this GATE 2025 Mechanical Engineering (ME) test, covering core subjects such as thermodynamics, fluid mechanics, strength of materials, theory of machines, and manufacturing engineering. With a well-balanced mix of conceptual and numerical questions, this test helps enhance problem-solving ability and technical understanding. Aligned with the latest exam pattern, it is ideal for improving accuracy, speed, and overall exam readiness.

Ask AI Tutor
5 left
Q1 View Question & Options
AI Tutor is solving this question...
Reading question context & options...
Ask your own doubt or choose a quick prompt: