The wall of a constant diameter pipe of length 1 m is heated uniformly with flux q′′ by wrapping a heater coil around it. The flow at the inlet to the pipe is hydrodynamically fully developed. The fluid is incompressible and the flow is assumed to be laminar and steady all through the pipe. The bulk temperature of the fluid is equal to 0°C at the inlet and 50°C at the exit. The wall temperatures are measured at three locations, P, Q and R, as shown in the figure. The flow thermally develops after some distance from the inlet. The following measurements are made:
| Point | P | Q | R |
| Wall Temp(°C) | 50 | 80 | 90 |
Among the locations P, Q and R, the flow is thermally developed at
Solution :
The correct answer is Q and R only.
1. Physical Principles of Uniform Wall Heat Flux ():
For a steady, incompressible, laminar flow in a pipe of constant diameter heated with a constant surface heat flux , the rate of heat addition per unit length is constant.
According to the first law of thermodynamics, the local bulk (mean) temperature of the fluid at any axial location along the pipe increases linearly from the inlet:
where:
• is the bulk temperature at the inlet (),
• is the perimeter of the pipe,
• is the mass flow rate, and
• is the specific heat capacity of the fluid.
2. Identifying the Thermally Fully Developed Region:
Newton's law of cooling relates the constant heat flux to the wall temperature and bulk temperature :
where is the convection heat transfer coefficient.
In the thermally fully developed region, the heat transfer coefficient becomes constant along the length of the pipe. Because is also constant, the temperature difference between the inner wall and the bulk fluid must remain constant:
3. Verification using the Given Measurement Locations:
The total length of the pipe is .
The bulk temperatures at the inlet and exit are:
• at
• at
Using the linear distribution of the bulk temperature:
From the schematic layout, the sensors P, Q, and R are located at:
• Point P:
• Point Q:
• Point R:
Now, we calculate the bulk temperatures at each location:
•
•
•
Next, we determine the temperature difference at each location using the measured wall temperatures:
• At Point P:
• At Point Q:
• At Point R:
Since the temperature difference is identical at locations Q and R (both equaling ), the heat transfer coefficient is constant over this segment. Therefore, the flow is thermally developed at Q and R only.
Completely free for students. Educators & coaching institutes get 2 months free Pro trial to create tests.
Access unlimited practice questions, detailed step-by-step solutions, and exam study materials — completely free for students.
Create and conduct professional online assessments with AI question generation, tab proctoring, and comprehensive batch management.
The GATE 2026 Mechanical Engineering (ME) examination scheduled for 14 February 2026 is one of the most important national-level competitive exams for engineering graduates aspiring for higher education and prestigious career opportunities in PSU and research organizations. Conducted annually at the national level, the GATE Mechanical Engineering paper evaluates candidates on core subjects such as Engineering Mechanics, Thermodynamics, Fluid Mechanics, Strength of Materials, Manufacturing Processes, and Machine Design, along with General Aptitude and Engineering Mathematics. This examination is a gateway for admission into M.Tech/Ph.D. programs at IITs, NITs, IISc, and other top institutions, as well as recruitment in major Public Sector Undertakings (PSUs) like ONGC, NTPC, BHEL, IOCL, and more. The GATE ME 2026 paper will test conceptual understanding, analytical thinking, and problem-solving ability, making strong preparation essential for success. Candidates are advised to practice previous year papers, mock tests, and focus on conceptual clarity for high scoring performance. This exam on 14/02/2026 is a crucial opportunity for mechanical engineering aspirants to secure their future in academia and industry.
Strengthen your preparation with this GATE 2025 Mechanical Engineering (ME) test, covering core subjects such as thermodynamics, fluid mechanics, strength of materials, theory of machines, and manufacturing engineering. With a well-balanced mix of conceptual and numerical questions, this test helps enhance problem-solving ability and technical understanding. Aligned with the latest exam pattern, it is ideal for improving accuracy, speed, and overall exam readiness.
Copyright © 2026 Combe Labs Private Limited. All Rights Reserved.