In a single phase transformer, the total iron loss is 2500 W at nominal voltage of 440 V and frequency 50 Hz. The total iron loss is 850 W at 220 V and 25 Hz. Then, at nominal voltage and frequency, the hysteresis loss and eddy current loss respectively are
Solution :
The correct option is 900 W and 1600 W.
Step-by-step explanation:
The total iron loss () in a transformer is the sum of hysteresis loss () and eddy current loss ():
The relationships of these losses with voltage () and frequency () depend on the ratio , which is proportional to the maximum flux density ():
Let us check the ratio of voltage to frequency for both given conditions:
Case 1: Nominal voltage and frequency .
Ratio:
Case 2: Voltage and frequency .
Ratio:
Since the ratio is constant in both cases, the maximum flux density remains constant. Under this condition, the hysteresis loss is directly proportional to frequency, and the eddy current loss is proportional to the square of the frequency:
Hysteresis Loss:
Eddy Current Loss:
where and are constants.
Therefore, the total iron loss can be written as:
Dividing both sides by yields:
Now, we substitute the values of both cases into this equation to solve for the constants and :
For Case 1 ( and ):
(Equation 1)
For Case 2 ( and ):
(Equation 2)
Subtracting Equation 2 from Equation 1:
Substituting back into Equation 2:
Finally, we calculate the individual losses at the nominal voltage and frequency ():
Hysteresis loss ():
Eddy current loss ():
Therefore, the hysteresis loss and eddy current loss are 900 W and 1600 W respectively.
Note: The attached image displays an AC circuit with a source frequency parameter of ω = 1 k rad/sec, a 4 mH inductor, a 0.5 mF capacitor, a 2 Ω resistor, and a load resistor RL. This diagram is unrelated to the single-phase transformer losses problem, which has been solved directly using the parameters specified in the question text.
Completely free for students. Educators & coaching institutes get 2 months free Pro trial to create tests.
Access unlimited practice questions, detailed step-by-step solutions, and exam study materials — completely free for students.
Create and conduct professional online assessments with AI question generation, tab proctoring, and comprehensive batch management.
Prepare for success in the GATE Electrical Engineering exam with our comprehensive Ultimate Revision Test. Designed for aspirants aiming for top scores, this test covers all key topics in the GATE EE syllabus, including Circuit Theory, Electromagnetic Fields, Power Systems, Electrical Machines, Control Systems, and Analog & Digital Electronics. Our revision test offers a balanced mix of theory-based and application-based questions that will help you assess your understanding and boost your problem-solving skills. With carefully selected questions that mirror the difficulty level of the actual GATE exam, this test will help you identify areas for improvement and fine-tune your exam strategy.
A comprehensive JEE Advanced 2022 Paper 1 designed to help aspirants understand the examination pattern, difficulty level, and question trends of JEE Advanced. This paper covers important concepts from Physics, Chemistry, and Mathematics, featuring a balanced mix of conceptual, numerical, and advanced application-based questions. It helps students strengthen conceptual understanding, enhance analytical and problem-solving skills, and improve speed and accuracy. Ideal for practice, revision, self-assessment, previous year trend analysis, concept reinforcement, and time management, this paper is a valuable resource for effective JEE Advanced preparation.
Copyright © 2026 Combe Labs Private Limited. All Rights Reserved.